60MW COMBINED CYCLE STEAM TURBINE Main Technical Data
Type
(Output)MW Rated extraction Straight condensing
Speed) (r/min)
Direction of Rotation
Steam Parameters
Exhaust Pressure (kPa.a)
Feed water (Temp.)℃
Pressure)Mpa.a Rated extraction/ Straight condensing
(Temp.)℃
LZN60-5.70/0.58
60
3000
CW view from downstream
5.70
515
4.83
33.8
LCZ60-5.70/1.57/0.58
60
3000
5.70/5.70
515/515
3.5
33.5
type
Height of operation floor(m)
Total weight of turbine proper(t)
Upper-half weight (t)
Total weight of turbine rotor(t)
External dimension(mm)
Central line height of turbine(mm)
LZN60-5.70/0.58
80
123
25.45
19.75
8330×7080×3310
800
LCZ60-5.70/1.57/0.58
80
123
24.85
20.34
8650.6×7080×3310
800
type
Steam injection
Steam extraction
(Cooling water temp.)℃
(Regeneration active system)
(Pressure)Mpa.a Rated extraction/ Straight condensing
(Temp.)℃ Rated extraction/ Straight condensing
(Flow)t/h Rated extraction/ Straight condensing
(Pressure) Mpa.a
(Temp.) ℃
(Flow)t/h Rated/Max.
LZN60-5.70/0.58
0.58
250
31
20
no
LCZ60-5.70/1.57/0.58
0.58/0.58
250/250
31
1.57
354
100/120
20
no