135~150MW STRAIGHT AIR CONDENSING STEAM TURBINE Main Technical Data
Type
(Output) MW] Rated extraction/ Straight condensing
Speed) (r/min)
Direction of Rotation
Rated Steam Parameters
(Exhaust Pressure) kPa.a Rated extraction/ Straight condensing
(Feed water temperature) ℃ Rated extraction/ Straight condensing
Pressure (Mpa.a)
(Temp)℃ Rated extraction/ Straight condensing
N135-13.24/535/535
135
3000
Clockwise Viewed downstream
13.24
535
4.9
238
N150-13.24/535/535
150
3000
13.24
535
5.2
245
C135-13.24/294/535/535
135/150
3000
13.24
535
5.2/5.2
245.8
type
Height of operation floor(m)
Total weight of turbine proper(t)
Total weight of turbine proper(t)
Maximum weight/overhaul( t)
External dimension(mm)
Central line height of turbine(mm)
N135-13.24/535/535
9.0
375
47
28
13600×7340×5200
900
N150-13.24/535/535
9.0
375
47
28
13600×7340×5200
900
C135-13.24/294/535/535
9.0
375
47
28
13600×7340×5200
900
Type
(Reheat Inlet Steam)
(Heating Steam Extraction)
(Maximum Extraction flow) t/h
(Regeneration active system)
(Pressure) Mpa.a Rated extraction/ Straight condensing
(Temp)℃ Rated extraction/ Straight condensing
(Flow)t/h Rated extraction/ Straight condensing
(Pressure) Mpa.a
(Temp)℃
(Flow) t/h Rated/Max
N135-13.24/535/535
2.12
535
2JG+1CY+4JD
N150-13.24/535/535
2.377
535
2JG+1CY+4JD
C135-13.24/294/535/535
2.567/2.394
535/535
389.3/363.2
0.294
150
200
2JG+1CY+4JD